Files
vectorcraft/apps
RealtaNuaandClaude Opus 5.5 4744c2f04b Fix #1373: --control without a valid port stops the desktop before it starts
--control took the next argument as its port and dropped it when it wasn't a number, so the app
started without a control server and `--control --automation-read-root DIR` opened DIR as a
document. automation_args::ControlArg now reads --control <port> or --control=<port> once and
requires a port from 1 to 65535; VECTORCRAFT_CONTROL_PORT must be one too, checked only when
--control isn't given so --control and --version win over a bad value. Errors go through the
same exit as the root flags (#1157).

Tests: unit tests in automation_args.rs; tests/automation_args.rs runs the binary for each bad
form and checks the exact message and a prompt failing exit.

Co-Authored-By: Claude Opus 5.5 (1M context) <[email protected]>
2026-10-12 18:56:36 +07:00
..